| Parameter | Specification |
| Max SWL Internal/Surface Lift | 165 t (0–50 m depth; full area, HS ≤4.0 m) |
| Max SWL Subsea Launch Zone | 165 t (air to 150 m; combined SWL + wire weight) |
| Max SWL Subsea Submerged | 165 t (>150 m to 3000 m; Normal/Extended AHC areas; offlead ≤2.0°) |
| Max SWL Sea Lift (Vessel-to-Vessel) | 165 t (HS=0.0 m; between upper/lower limits for lift-off/set-down) |
| Outreach | Up to 54 m (derates to ~50 t @ 50 m radius) |
| Notes | AHC limited to Normal area for lift-off from seabed; Extended for submerged handling. |
| Parameter | Specification |
| Max SWL Internal/Surface Lift | 32 t (~10 m radius; full area, HS ≤4.0 m; for lighter tools) |
| Max SWL Subsea Lift | 17 t (air/submerged to 3000 m; combined SWL + wire weight; offlead ≤5.0°) |
| Max SWL Sea Lift (Vessel-to-Vessel) | 32 t (HS ≤0.5 m; above lower limit for lift-off/set-down) |
| Max SWL Personnel Lift | 1.5–2 t (basket; HS ≤2.0 m, wind ≤10 m/s, daylight visibility) |
| Outreach | Up to 40–52 m (derates to ~10 t @ 40 m radius) |
| Notes | Full AHC integration; no AHC limitations vs. main hoist. |
| Aspect | Details |
| Overall Condition | Good structural integrity; visually operational, non-functional due to missing HMI panel and MRU unit. Last operation unknown; cold-stacked ~8 years. Wire ropes and sheaves OK (no breaks, minimal wear). Corrosion on boom, hooks, valves, and railings requires treatment. No load test or overhaul certificates available. |
| Key Deficiencies (Critical/Severe) |
- Missing HMI (prevents startup/testing).
- Corroded hook blocks (need full overhaul/load test).
- Insufficient greasing (slewing bearings/sheaves).
- Hydraulic: Filters overdue; tank sludge; damaged hoses/cylinders need testing.
|
| Recommendations | Source HMI/MRU/manual Vol. #2; conduct EMAG on wires, proof load test, and full hydraulic/gearbox service before removal. Estimated prep: 2-4 weeks with parts. |